Individual Pair Shielding
Each twisted pair has a dedicated screen to help limit interference between adjacent signal groups within the cable.
ROLAN CABLE · TRVVPPS SERIES
Keep multiple signal circuits organized in one moving cable. TRVVPPS combines twisted pairs, individual pair screens and an overall shielding system for control and signal wiring in industrial automation.
Fine-stranded oxygen-free copper conductors and a flexible, oil-resistant PVC jacket support repeated bending in compatible cable carriers.

*Flex life and travel speed depend on cable size, bending radius, travel distance, acceleration and installation. Confirm the applicable test conditions and operating limits for your selected construction.
PRODUCT FEATURES
A cable structure focused on circuit separation, shielding and mechanical flexibility.
Each twisted pair has a dedicated screen to help limit interference between adjacent signal groups within the cable.
An overall screen adds protection around the pair assembly. Final EMC performance also depends on connectors, routing and shield termination.
The black elastic PVC jacket provides the oil and abrasion resistance listed for this model. Match the cable to the actual motion and exposure conditions.
CABLE CONSTRUCTION
Separate circuits within a shared cable assembly while retaining a flexible outer construction.
Oxygen-free copper strands form the conductors for flexible control and signal circuits.
Separate insulated cores support circuit identification. Confirm the insulation compound in the approved construction sheet.
Two insulated cores form each pair, keeping the conductors of a signal circuit together.
Foil and tinned-copper braid shielding isolate the pair groups. Confirm the detailed shield build for the selected version.
Wrapping and fillers organize the pair assembly beneath the overall shielding system.
A matte black jacket encloses the assembly for flexible, oil-resistant machine wiring.
PRODUCT DETAILS
Actual product photos show the jacket, conductor groups and shielding layers.
TECHNICAL INFORMATION
Use the fixed and moving installation limits separately when reviewing your application.
| Model | TRVVPPS |
|---|---|
| Cable Type | Individually shielded twisted-pair drag chain cable |
| Conductor | Fine-stranded oxygen-free copper |
| Core Insulation | Compound to be confirmed in the approved specification* |
| Shielding | Individual pair screens plus overall shielding; foil and tinned-copper braid construction |
| Outer Jacket | Elastic, oil-resistant PVC; standard matte black |
| Rated Voltage | Below 0.5 mm²: 300/300 V 0.5 mm² and above: 300/500 V |
| Voltage Test | 2 kV AC for 5 minutes |
| Fixed Temperature Range | −30°C to +105°C |
| Moving Temperature Range | −15°C to +90°C |
| Travel Speed | Overhead: up to 3 m/s Gliding: up to 2 m/s |
| Catalog Flex Life | 20 million cycles, subject to confirmed test and installation conditions |
| Minimum Bending Radius | Fixed: 6.5 × D Moving, travel below 10 m: 7.5 × D Moving, travel of 10 m or more: 10 × D |
| Standard Packaging | 100 m per roll; other lengths available on request |
D = finished cable outside diameter. Travel speeds describe mechanical movement, not data transmission rate. The cycle figure is a catalog reference, not a service-life guarantee at every combination of speed, radius and travel. *Confirm the core insulation material in the approved construction sheet before ordering.
SIZES, DIMENSIONS & WEIGHT
Compare available configurations by pair count, conductor size, outside diameter and cable weight. Each twisted pair contains two insulated cores: 4 cores = 2P, 6 cores = 3P, and 8 cores = 4P.
| Model | Pair Count | Core Count | Conductor Size (mm² / core) |
Insulated Core OD (mm) |
Overall Cable OD (mm) |
Weight (kg / 100 m) |
|---|---|---|---|---|---|---|
| TRVVPPS | 2P | 4 | 0.2 | 0.9 | 5.8 | 4.16 |
| TRVVPPS | 3P | 6 | 0.2 | 0.9 | 7.0 | 6.72 |
| TRVVPPS | 4P | 8 | 0.2 | 0.9 | 7.8 | 8.37 |
| TRVVPPS | 5P | 10 | 0.2 | 0.9 | 8.2 | 11.90 |
| TRVVPPS | 6P | 12 | 0.2 | 0.9 | 9.3 | 13.39 |
| TRVVPPS | 7P | 14 | 0.2 | 0.9 | 10.0 | 14.87 |
| TRVVPPS | 8P | 16 | 0.2 | 0.9 | 10.6 | 16.53 |
| TRVVPPS | 10P | 20 | 0.2 | 0.9 | 11.6 | 19.22 |
| TRVVPPS | 2P | 4 | 0.3 | 1.2 | 6.3 | 6.03 |
| TRVVPPS | 3P | 6 | 0.3 | 1.2 | 7.4 | 9.20 |
| TRVVPPS | 4P | 8 | 0.3 | 1.2 | 8.2 | 10.98 |
| TRVVPPS | 5P | 10 | 0.3 | 1.2 | 8.8 | 12.97 |
| TRVVPPS | 6P | 12 | 0.3 | 1.2 | 10.0 | 14.60 |
| TRVVPPS | 7P | 14 | 0.3 | 1.2 | 10.2 | 17.45 |
| TRVVPPS | 8P | 16 | 0.3 | 1.2 | 11.2 | 19.49 |
| TRVVPPS | 10P | 20 | 0.3 | 1.2 | 12.0 | 23.04 |
| TRVVPPS | 2P | 4 | 0.5 | 1.5 | 8.0 | 8.90 |
| TRVVPPS | 3P | 6 | 0.5 | 1.5 | 8.6 | 12.23 |
| TRVVPPS | 4P | 8 | 0.5 | 1.5 | 9.6 | 15.13 |
| TRVVPPS | 5P | 10 | 0.5 | 1.5 | 10.5 | 17.98 |
| TRVVPPS | 6P | 12 | 0.5 | 1.5 | 12.0 | 21.81 |
| TRVVPPS | 7P | 14 | 0.5 | 1.5 | 12.4 | 24.24 |
| TRVVPPS | 8P | 16 | 0.5 | 1.5 | 13.2 | 26.93 |
| TRVVPPS | 10P | 20 | 0.5 | 1.5 | 14.2 | 31.68 |
| TRVVPPS | 2P | 4 | 0.75 | 1.8 | 8.9 | 11.50 |
| TRVVPPS | 3P | 6 | 0.75 | 1.8 | 10.8 | 16.03 |
| TRVVPPS | 4P | 8 | 0.75 | 1.8 | 11.6 | 19.58 |
| TRVVPPS | 5P | 10 | 0.75 | 1.8 | 12.6 | 23.09 |
| TRVVPPS | 6P | 12 | 0.75 | 1.8 | 14.2 | 27.39 |
| TRVVPPS | 7P | 14 | 0.75 | 1.8 | 14.5 | 30.48 |
| TRVVPPS | 8P | 16 | 0.75 | 1.8 | 15.5 | 34.29 |
| TRVVPPS | 10P | 20 | 0.75 | 1.8 | 16.6 | 40.80 |
| TRVVPPS | 2P | 4 | 1.0 | 2.1 | 11.6 | 15.63 |
| TRVVPPS | 3P | 6 | 1.0 | 2.1 | 12.0 | 19.07 |
| TRVVPPS | 4P | 8 | 1.0 | 2.1 | 13.2 | 24.09 |
| TRVVPPS | 5P | 10 | 1.0 | 2.1 | 14.2 | 28.04 |
| TRVVPPS | 6P | 12 | 1.0 | 2.1 | 15.5 | 32.74 |
| TRVVPPS | 2P | 4 | 1.5 | 2.4 | 12.6 | 18.62 |
| TRVVPPS | 3P | 6 | 1.5 | 2.4 | 13.4 | 24.18 |
| TRVVPPS | 4P | 8 | 1.5 | 2.4 | 14.2 | 29.19 |
| TRVVPPS | 5P | 10 | 1.5 | 2.4 | 15.5 | 35.09 |
| TRVVPPS | 6P | 12 | 1.5 | 2.4 | 16.8 | 41.04 |
| TRVVPPS | 2P | 4 | 2.5 | 2.8 | 14.0 | 22.90 |
| TRVVPPS | 3P | 6 | 2.5 | 2.8 | 14.8 | 30.92 |
| TRVVPPS | 4P | 8 | 2.5 | 2.8 | 16.4 | 38.90 |
TRVVPPS 2P × 0.3 mm² means 2 twisted pairs, 4 insulated cores in total, and a nominal conductor cross-section of 0.3 mm² per core. This configuration has an insulated core OD of 1.2 mm, an overall cable OD of 6.3 mm, and a listed weight of 6.03 kg per 100 m.
OD = outside diameter. Insulated core OD is the diameter of one insulated conductor; overall cable OD is the finished cable diameter. All weights are stated in kilograms per 100 meters. Confirm dimensional and weight tolerances before ordering.
TYPICAL APPLICATIONS
The scenarios below illustrate selection use cases. Confirm electrical, mechanical and interface requirements for the complete system.
Multi-pair control and signal circuits routed between a machine frame and moving slides or carriages.
Selection focus:
Carrier bend radius, stroke length, coolant or oil exposure and shield termination.
Signal wiring for robot tracks, positioning tables and supported cable-carrier movements around robotic workcells.
Selection focus:
Acceleration and motion type. Confirm torsional suitability separately for rotating joints or robot dress packs.
Separate sensor and control circuits serving moving packaging heads, feeders or transfer mechanisms.
Selection focus:
Cycle frequency, temperature, cleaning exposure and the available installation space.
Control wiring on shuttles, transfer carriages and linear handling equipment using compatible cable carriers.
Selection focus:
Overhead or gliding travel, acceleration, cable weight and the full movement distance.
Several paired signal circuits within one cable serving moving fixtures, tooling or assembly modules.
Selection focus:
Pair allocation, signal compatibility, connector layout and separation from power wiring.
Paired circuits between stationary instrumentation and movable test fixtures or positioning stages.
Selection focus:
Signal level, cable length, capacitance, impedance and shield connection requirements.
Individual shielding does not by itself establish Ethernet, fieldbus, encoder or other protocol compliance. Confirm the electrical transmission requirements with the equipment manufacturer and ROLAN CABLE.
A useful cable specification includes both the circuit requirements and the way the machine moves.
Install according to the confirmed cable and carrier instructions. Avoid twisting, crushing or tensioning the cable within the carrier, and maintain the approved dynamic bending radius.
PRODUCT FAQ
Pair screens help separate adjacent circuits inside the cable. The overall shield addresses interference around the complete assembly. Effective shielding also requires suitable routing, connectors and termination.
No. Flex life depends on the selected construction and movement conditions. Request the corresponding test conditions, including bending radius, travel, speed and acceleration, before using the catalog figure for your design.
Repeated bending and torsion are different loads. Do not assume a drag chain specification covers rotational movement. Provide the twist angle, active cable length and duty cycle for a separate suitability review.
Discuss pair count, conductor size, shielding, jacket color, printing and packaging with ROLAN CABLE. Final materials and dimensions should be recorded in the approved specification before production.
Send your pair count, conductor size and motion requirements. ROLAN CABLE can review the construction, provide dimensional data and prepare a quotation.