30 Million+ Flex Cycles
Engineered for more than 30 million bending cycles under specified installation and motion conditions.
TRVVP Series · Shielded Drag Chain Cable
High-flex signal and power cable with aluminum-foil plus tinned-copper-braid shielding, engineered for high-speed drag chains and electrically noisy industrial environments.

Rolan TRVVP is a high-flex shielded drag chain cable designed for stable signal transmission during continuous reciprocating movement.
Ultra-fine oxygen-free copper conductors improve flexibility, HDPE insulation supports reliable electrical performance, and the aluminum-foil plus tinned-copper-braid shield provides strong electromagnetic interference protection. A semi-matte polyether PUR jacket adds resistance to oil, abrasion, acids, alkalis, corrosion and mechanical stress.
Every layer is selected to balance flexibility, mechanical durability and signal integrity in demanding moving equipment.
Engineered for more than 30 million bending cycles under specified installation and motion conditions.
Aluminum-foil wrapping plus tinned-copper-wire braid delivers strong electromagnetic interference protection.
High braid coverage supports stable signal transmission around motors, drives and industrial control equipment.
Multi-stranded oxygen-free copper with approximately 0.08 mm strands improves flexibility and fatigue resistance.
Color-coded HDPE-insulated cores support reliable electrical separation and low signal loss during movement.
Polyether PUR resists oil, abrasion, acids, alkalis, corrosion, repeated bending and mechanical tension.
Use these values for initial product selection. Final construction and performance must be confirmed against the approved cable drawing and actual drag-chain conditions.
| Product Model | TRVVP high-flex shielded drag chain cable |
|---|---|
| Conductor | Multi-stranded ultra-fine oxygen-free copper, approx. 0.08 mm strand diameter |
| Core Insulation | HDPE, color-coded cores |
| Filler | Cotton yarn filler |
| Inner Wrapping | Non-woven tape |
| Shielding | Aluminum-foil wrapping plus tinned-copper-wire braid |
| Shield Coverage | ≥92% |
| Outer Jacket | Polyether-based PUR, semi-matte black |
| Rated Voltage | 300/300 V below 0.5 mm²; 300/500 V at 0.5 mm² and above |
| Voltage Test | 2 kV AC for 5 minutes |
| Fixed Installation Temperature | -50°C to +125°C |
| Dynamic Installation Temperature | -30°C to +105°C |
| Maximum Unsupported Speed | Up to 3 m/s |
| Maximum Gliding Speed | Up to 2 m/s |
| Flexing Life | More than 30 million cycles under specified conditions |
| Standard Packing | 100 meters per roll; weight depends on configuration |
Ultra-fine stranded construction supports high-frequency bending and stable electrical transmission.
Color-coded cores and filler help maintain electrical separation and a balanced cable structure.
Combined shielding improves anti-interference performance and provides at least 92% braid coverage.
Semi-matte black jacket for wear, oil, chemical and mechanical resistance in moving systems.
D refers to the actual cable outer diameter. Correct routing, separation, clamping and drag-chain installation are essential for achieving the expected service life.
Recommended where continuous movement and strong electromagnetic interference protection are both required.
Shielded signal and control wiring for robot arms and automated work cells.
Dynamic cable routing near motors, drives and electrically noisy machining equipment.
Continuous-motion control and signal transmission for assembly and inspection systems.
Oil-resistant moving cable for high-cycle molding and material-handling equipment.
Flexible shielded wiring for rapid repetitive movement and precision control.
Suitable for systems exposed to oil, abrasion, acids, alkalis and mechanical stress.
Share the electrical requirements, motion profile, installation environment and order quantity for a matched construction.
Configure the number and identification colors of insulated conductors.
Select the cross-section according to load, voltage drop and circuit design.
Optimize foil, braid coverage and grounding arrangement for the EMC environment.
Project-specific jacket color and enhanced environmental resistance options.
Custom model, meter marks, company name, coil or reel length.
Labels, cartons, reels, pallets and documentation matched to the order.
Inspection points are aligned with the approved cable construction and project test requirements.
Conductor, insulation, shielding and jacket material identity and appearance.
Conductor, insulation, braid and finished cable dimensions checked during production.
Braid coverage, continuity and shield construction checked against the approved design.
Continuity, conductor resistance and 2 kV AC voltage test as specified.
Bending performance, printing, length, appearance and packaging verified before release.
Available documents depend on the confirmed model, customer requirements and destination market.
Approved structure, dimensions and operating conditions.
Construction and identification details for project approval.
Applicable electrical, shielding and flex-test records.
Relevant material and compliance documentation on request.
The correct cable must match both the electrical circuit and the real movement profile.
TRVVP includes an aluminum-foil and tinned-copper-braid shielding structure for stronger electromagnetic interference protection. TRVV is the unshielded version.
It is designed for more than 30 million cycles under specified conditions. Actual life depends on bend radius, travel, speed, acceleration, installation and environment.
It is recommended near motors, frequency converters, servo systems and other electrically noisy equipment where stable signal transmission is important.
Yes. Provide the circuit requirements, voltage, current, travel distance and quantity for engineering review.
Please provide core count, conductor size, rated voltage, bend radius, travel distance, speed, acceleration, temperature, shielding requirement and order quantity.
Our team will help match the conductor size, core count, shield structure, cable diameter and minimum bending radius.