• 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable

PUR 30 Million Cycles TRVVP High-Flex Shielded Drag Chain Cable

30-million-cycle TRVVP high-flex shielded drag chain cable with aluminum-foil and tinned-copper-braid shielding, ≥92% shield coverage and an oil-resistant polyether PUR jacket for CNC machines, robots and automated production lines.
Specifications
Insulation Material:
HDPE (High-Density Polyethylene)
Jacket Material:
Polyether-Based PUR (Polyurethane)
Rated Voltage::
< 0.5 mm²: 300/300 V; ≥ 0.5 mm²: 300/500 V
Temperature Range:
-50°C to +125°C
Bending Life:
30 Million Cycles under Specified Conditions
Conductor Material:
0.15-0.3mm2 conductors: tinned copper;>0.5mm2:oxygen-free copper
Shielding:
Tinned Copper Braided Shield Layer+Aluminum Foil Shield Wrapping
Download
View all downloads
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable
  • 30 Million Cycle PUR High-Flex Shielded Drag Chain Cable,rolancable.com,30 Million Cycle PUR Oil Resistant Shielded Drag Chain Cable

Description

TRVVP Series · Shielded Drag Chain Cable

30 Million Cycle PUR Shielded Cable

High-flex signal and power cable with aluminum-foil plus tinned-copper-braid shielding, engineered for high-speed drag chains and electrically noisy industrial environments.

30M+ Flex Cycles≥92% Shield CoveragePolyether PUR JacketUp to 3 m/s
30 million cycle TRVVP PUR shielded drag chain cable
30M+Specified flex cycles
≥92%Shield coverage
3 m/sUnsupported speed
Product Overview

High-speed motion with strong interference protection.

Rolan TRVVP is a high-flex shielded drag chain cable designed for stable signal transmission during continuous reciprocating movement.

Ultra-fine oxygen-free copper conductors improve flexibility, HDPE insulation supports reliable electrical performance, and the aluminum-foil plus tinned-copper-braid shield provides strong electromagnetic interference protection. A semi-matte polyether PUR jacket adds resistance to oil, abrasion, acids, alkalis, corrosion and mechanical stress.

✓Dual shielding structure
✓High-speed drag-chain duty
✓Oil-resistant PUR jacket
✓OEM construction available
Key Features

Designed for motion. Protected from noise.

Every layer is selected to balance flexibility, mechanical durability and signal integrity in demanding moving equipment.

01

30 Million+ Flex Cycles

Engineered for more than 30 million bending cycles under specified installation and motion conditions.

02

Dual Shielding

Aluminum-foil wrapping plus tinned-copper-wire braid delivers strong electromagnetic interference protection.

03

≥92% Shield Coverage

High braid coverage supports stable signal transmission around motors, drives and industrial control equipment.

04

Ultra-Fine Conductor

Multi-stranded oxygen-free copper with approximately 0.08 mm strands improves flexibility and fatigue resistance.

05

HDPE Core Insulation

Color-coded HDPE-insulated cores support reliable electrical separation and low signal loss during movement.

06

Durable PUR Jacket

Polyether PUR resists oil, abrasion, acids, alkalis, corrosion, repeated bending and mechanical tension.

Technical Specifications

Electrical and mechanical reference data.

Use these values for initial product selection. Final construction and performance must be confirmed against the approved cable drawing and actual drag-chain conditions.

Product Model TRVVP high-flex shielded drag chain cable
Conductor Multi-stranded ultra-fine oxygen-free copper, approx. 0.08 mm strand diameter
Core Insulation HDPE, color-coded cores
Filler Cotton yarn filler
Inner Wrapping Non-woven tape
Shielding Aluminum-foil wrapping plus tinned-copper-wire braid
Shield Coverage ≥92%
Outer Jacket Polyether-based PUR, semi-matte black
Rated Voltage 300/300 V below 0.5 mm²; 300/500 V at 0.5 mm² and above
Voltage Test 2 kV AC for 5 minutes
Fixed Installation Temperature -50°C to +125°C
Dynamic Installation Temperature -30°C to +105°C
Maximum Unsupported Speed Up to 3 m/s
Maximum Gliding Speed Up to 2 m/s
Flexing Life More than 30 million cycles under specified conditions
Standard Packing 100 meters per roll; weight depends on configuration
Actual service life depends on bend radius, travel distance, speed, acceleration, installation quality and operating environment. Use the approved technical drawing for production and installation.
CuCuCuCu
PUR Outer JacketTinned Copper BraidAluminum FoilHDPE Insulated Cores
Cable Construction

Dual shielding from core to jacket.

01

Oxygen-Free Copper Conductor

Ultra-fine stranded construction supports high-frequency bending and stable electrical transmission.

02

HDPE Insulation & Cotton Filler

Color-coded cores and filler help maintain electrical separation and a balanced cable structure.

03

Foil + Tinned Copper Braid

Combined shielding improves anti-interference performance and provides at least 92% braid coverage.

04

Polyether PUR Outer Jacket

Semi-matte black jacket for wear, oil, chemical and mechanical resistance in moving systems.

Installation Guidance

Recommended minimum bending radius.

D refers to the actual cable outer diameter. Correct routing, separation, clamping and drag-chain installation are essential for achieving the expected service life.

Fixed Installation6.5 × DMinimum recommended bending radius.
Dynamic Travel Below 10 m7.5 × DFor moving travel shorter than 10 meters.
Dynamic Travel 10 m or Above10 × DFor longer travel and more demanding systems.
Applications

Reliable signals in demanding motion systems.

Recommended where continuous movement and strong electromagnetic interference protection are both required.

ROBOT

Industrial Robots

Shielded signal and control wiring for robot arms and automated work cells.

CNC

CNC Machine Tools

Dynamic cable routing near motors, drives and electrically noisy machining equipment.

LINE

Automated Production Lines

Continuous-motion control and signal transmission for assembly and inspection systems.

MOLD

Injection Molding Machines

Oil-resistant moving cable for high-cycle molding and material-handling equipment.

PACK

Packaging Machinery

Flexible shielded wiring for rapid repetitive movement and precision control.

HARSH

Harsh Environments

Suitable for systems exposed to oil, abrasion, acids, alkalis and mechanical stress.

Customization

Configure it for your equipment.

Share the electrical requirements, motion profile, installation environment and order quantity for a matched construction.

01 / CORES

Core Count

Configure the number and identification colors of insulated conductors.

02 / SIZE

Conductor Size

Select the cross-section according to load, voltage drop and circuit design.

03 / SHIELD

Shield Structure

Optimize foil, braid coverage and grounding arrangement for the EMC environment.

04 / JACKET

Color & Material

Project-specific jacket color and enhanced environmental resistance options.

05 / MARKING

Printing & Length

Custom model, meter marks, company name, coil or reel length.

06 / PACKING

OEM Packaging

Labels, cartons, reels, pallets and documentation matched to the order.

Quality Control

Checked for electrical and mechanical consistency.

Inspection points are aligned with the approved cable construction and project test requirements.

01

Incoming Material Inspection

Conductor, insulation, shielding and jacket material identity and appearance.

02

In-Process Dimensional Control

Conductor, insulation, braid and finished cable dimensions checked during production.

03

Shielding Verification

Braid coverage, continuity and shield construction checked against the approved design.

04

Electrical & Voltage Test

Continuity, conductor resistance and 2 kV AC voltage test as specified.

05

Flexing & Final Inspection

Bending performance, printing, length, appearance and packaging verified before release.

Documentation

Support for technical project review.

Available documents depend on the confirmed model, customer requirements and destination market.

DATA

Technical Datasheet

Approved structure, dimensions and operating conditions.

DRAW

Cable Drawing

Construction and identification details for project approval.

TEST

Inspection Report

Applicable electrical, shielding and flex-test records.

MAT

Material Records

Relevant material and compliance documentation on request.

FAQ

Questions before selection.

The correct cable must match both the electrical circuit and the real movement profile.

What is the difference between TRVV and TRVVP?

TRVVP includes an aluminum-foil and tinned-copper-braid shielding structure for stronger electromagnetic interference protection. TRVV is the unshielded version.

Can the cable withstand more than 30 million bending cycles?

It is designed for more than 30 million cycles under specified conditions. Actual life depends on bend radius, travel, speed, acceleration, installation and environment.

Where is the dual-shielded cable recommended?

It is recommended near motors, frequency converters, servo systems and other electrically noisy equipment where stable signal transmission is important.

Can core count and conductor size be customized?

Yes. Provide the circuit requirements, voltage, current, travel distance and quantity for engineering review.

What information is needed for a quotation?

Please provide core count, conductor size, rated voltage, bend radius, travel distance, speed, acceleration, temperature, shielding requirement and order quantity.

Start Your Inquiry

Send us your motion and EMC requirements.

Our team will help match the conductor size, core count, shield structure, cable diameter and minimum bending radius.

Core CountConductor SizeVoltageBend RadiusTravel SpeedTemperatureQuantity
Request a Factory Quote
Specifications are subject to the approved cable drawing, test conditions and order confirmation.

Contact Us

E-mail : sales@rolancable.com
E-mail : sales@rolancable.com
Tel/Whatsapp: +86 19120640642
Tel/Whatsapp: +86 19120640642
Contact Us
Wechat
Contact Us
Whatsapp
Request a Quote Get Started Today
Email*
Phone/Whatsapp*
Company Name
Image Upload
File Upload
Message*
Our most frequently asked questions

Does Rolan Cable provide customized cable solutions?

Yes. We provide customized cable solutions based on your drawings, specifications and application requirements. Custom options can include conductor size, number of cores, shielding structure, insulation and jacket materials, cable diameter, color, printing and packaging length.

How can I request a quotation or place an order?

Please send us the cable model or specification, conductor size, number of cores, required quantity and application information. If you have a drawing or datasheet, you can also send it to us. Our sales team will review the requirements and provide a quotation accordingly.

What shipping terms and delivery methods do you support?

We can support common international trade terms such as EXW, FOB and CIF depending on the order and customer requirements. Shipments can be arranged by express courier, air freight or sea freight according to the quantity, destination and delivery requirements.

What is the typical lead time for cable orders?

Lead time depends on the cable specification, quantity, customization requirements and current production schedule. Standard or available cable specifications can usually be arranged faster, while customized cables may require additional production time. Please contact us with your required specification and quantity for an accurate lead-time confirmation.

What is the MOQ for your cables?

The MOQ depends on the cable type, specification and customization requirements. For some standard specifications, samples or small-quantity orders may be available. For customized cables, the MOQ will be confirmed after reviewing the detailed specification.

Can I get cable samples for testing?

Yes. Samples are available for many cable specifications. Please send us the cable model or specification, application and required sample length. Our team will check availability and confirm the sample and shipping arrangements with you.

Can you help me select the right cable for my application?

Yes. Please provide your application, conductor size, number of cores, voltage, movement requirements, bending radius, operating temperature and other environmental conditions. Our team can recommend a suitable cable construction and specification based on your requirements.
Leave a message
Email*
Phone/Whatsapp*
Company Name
Image Upload
File Upload
Message*
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.