Skip to content

Industrial cable solutions
built around your equipment

Start with the motion, electrical requirements and installation environment—not only the cable model. Rolan Cable helps review drag-chain, servo, flat traveling, energy storage, EV high-voltage and stage lighting requirements before final specifications are confirmed.

6Application families
8Customization steps
1:1Application review
Application Library

Find the right cable by application

Each application starts with a different risk: repeated flexing, signal integrity, suspended load, high-voltage DC insulation, connector fit or stage-equipment movement. Use the selection checks and installation limits below to prepare a more complete RFQ.

Industrial automation equipment using flexible drag chain cable
Automation & Machine Tools

Continuous reciprocating motion

Drag Chain & Industrial Automation

For automated machinery where cables operate inside a cable carrier and repeatedly bend during each machine cycle.

TRVVTRVVPTRVVPSTRVVPPSTRVIndustrial Drag Chain Ethernet Cable
View drag chain cables

Selection checks

  • Fixed or drag-chain operation, travel, speed, acceleration and minimum bend radius
  • Temperature and exposure to machine oil, lubricant or motor interference
  • Cycle data must be reviewed with its test conditions; it cannot be equated directly to equipment service life

Installation limits

  • Designed for reciprocating flexing inside a drag chain—not for unverified continuous torsion or reeling
  • Do not twist the cable; respect the specified bend radius, allow movement space and avoid overfilling the carrier
  • Secure both cable ends and connect the shield according to equipment grounding requirements
Available documentation: product specification sheet, bending test records, test equipment photos or video, construction data and relevant factory inspection records—where applicable and subject to confirmation.
Industrial robotics and servo-driven automation equipment
Robotics & Servo Systems

Power and signal, selected separately

Servo Power & Feedback

For servo motors, drives, feedback devices and automated equipment where power supply and signal transmission have different electrical requirements.

Servo Motor Power CableServo Encoder & Feedback CableVFD & Frequency Converter CableIndustrial Sensor Cable
View servo cables

Selection checks

  • Servo motor rated voltage, current, conductor size, cores and PE grounding requirement
  • Drag-chain travel, speed, acceleration, bend radius and operating environment
  • Servo motor, encoder and drive interface plus electrical requirements

Installation limits

  • A servo motor power cable cannot directly replace an encoder or feedback signal cable
  • Meet drag-chain movement and bend-radius requirements; avoid torsion and overstretching
  • Ground the shield as required by the servo drive system; continuous torsion, ultra-small radius, high temperature or other special conditions require separate technical confirmation
Available documentation: product specification sheet, construction photos, shielding data, factory inspection records and dynamic bending test data—where applicable and subject to confirmation.
Flat traveling cable for lifting and moving equipment
Cranes, Lifts & Conveying

Suspended motion with controlled load support

Flat Traveling Cable

For cranes, hoists, lifts, elevators, automatic storage equipment and moving conveyors that need vertical suspension or reciprocating power supply.

YFFB+2GYFFBTVVBTVVB+2G
View flat traveling cables

Selection checks

  • Equipment type, suspension length, travel, speed, bending direction and minimum bend radius
  • Support method, pulling force and installation environment
  • Dual steel wires are for mechanical support and tensile assistance—not conductors or shield

Installation limits

  • Avoid pull force, torsion and abnormal side bending beyond the design range
  • Confirm steel-wire load capacity using suspension length, travel, speed and actual load
  • The cable body should not be treated as the equipment’s sole load-bearing member
Available documentation: product specification sheet, construction photos, dual steel-wire construction data, bending test data and relevant factory inspection records—where applicable and subject to confirmation.
Battery energy storage system and power conversion equipment
Battery Storage Systems

Internal high-voltage DC connections

Energy Storage Equipment

For power connections inside lithium battery storage systems, battery cabinets and clusters, PCS converters, combiner boxes and storage inverters.

ES-RYJ-125ES-RYJYJ-125ES-RVV
View energy storage cables

Selection checks

  • Connection position, system DC voltage, operating current and conductor size
  • Operating temperature, fixed or moving installation, terminal method and available space
  • Conductor size must match system current, temperature rise and installation method

Installation limits

  • Confirm bend radius against the routing space inside the equipment
  • Match terminal crimping to conductor size and connector specification; avoid loose terminals, overbending and long-term mechanical tension
  • High-frequency movement or drag-chain use requires separate confirmation and should not be assumed from fixed-installation conditions
Available documentation: product specification sheet, conductor and insulation construction data, dielectric and continuity inspection records, product photos and relevant test data—where applicable and subject to confirmation.
EV charging and high-voltage power connection equipment
EV & New Energy Systems

High-voltage power routing for vehicles and equipment

EV High-Voltage Connection

For electric vehicles, high-voltage battery packs, motor controllers, drive systems, power distribution, on-board charging and new-energy equipment connections.

EVRPEVREVEVP
View EV high-voltage cables

Selection checks

  • Vehicle or equipment system voltage, operating current, conductor size and installation position
  • Operating temperature, minimum bend radius, shielding and grounding requirements
  • Terminal and connector specifications; battery pack, motor, controller and charging interfaces require separate confirmation

Installation limits

  • Avoid an excessively small bend radius, long-term mechanical tension, sharp-edge compression and direct contact with hot components
  • Ground and terminate the shield according to the vehicle or equipment electrical design
  • Match connectors, terminals and conductor size; continuous dynamic bending, drag-chain use or high-frequency torsion requires separate technical confirmation
Available documentation: product specification sheet, conductor, insulation and jacket construction data, shielding data, dielectric and continuity test records, product photos and relevant inspection records—where applicable and subject to confirmation.
Load-bearing shielded stage lighting cable
Stage & Entertainment Equipment

Suspended power and signal with load-bearing review

Stage Lighting & Entertainment

For stage lighting, studio and performance equipment, lighting bars, lifting frames and moving fixtures that require suspended or moving connections.

WTDL Load-Bearing Shielded Stage Lighting Cable
View stage lighting cable

Selection checks

  • Equipment type, suspension length, lifting travel, speed, load requirement and bending method
  • Power or signal purpose, shielding requirement and site installation environment
  • Repeated movement with lighting bars, lifting frames or stage machinery requires focused review of the load-bearing structure and dynamic bending conditions

Installation limits

  • Confirm the load requirement using actual suspension length and load
  • Avoid mechanical tension, torsion or abnormal side bending beyond the design range
  • Connect the shield according to the control system and equipment grounding requirements; high-speed reeling, continuous torsion or special outdoor conditions require separate technical confirmation
Available documentation: product specification sheet, construction photos, load-bearing structure data, shielding data, bending or movement test records and relevant factory inspection records—where applicable and subject to confirmation.
Quick Reference

Selection matrix

Use this table as an initial screening tool. Final construction, dimensions, materials and performance requirements remain subject to the confirmed specification and technical review.

Compare application priorities
Application Start with these checks Cable family Key installation limit
Drag chain & automationReciprocating motion Travel, speed, acceleration, bend radius, temperature and oil exposure TRVV / TRVVP / TRVVPS / TRVVPPS / TRV and drag chain Ethernet cable Use for verified reciprocating flexing inside a carrier; continuous torsion and reeling require separate confirmation.
Servo power & feedbackMotion control Motor voltage and current, cores, PE, drive interface, travel and environment Servo power, encoder/feedback, VFD and sensor cable Power and encoder/feedback cables are not interchangeable; special dynamic conditions require review.
Flat traveling cableSuspended movement Suspension length, travel, speed, bend direction, support method and pull force YFFB / YFFB+2G / TVVB / TVVB+2G Steel wires share mechanical load; do not use the cable body as the sole support member.
Energy storageInternal DC power System DC voltage, current, conductor size, temperature, terminals and routing space ES-RYJ-125 / ES-RYJYJ-125 / ES-RVV Confirm terminal and bend requirements; high-frequency movement or drag-chain use requires separate review.
EV high voltageVehicle and equipment power System voltage and current, temperature, bend radius, shielding, grounding and connectors EV / EVP / EVR / EVRP Avoid edge compression and hot-component contact; continuous dynamic use requires technical confirmation.
Stage lightingSuspended and moving equipment Suspension length, lift travel, load, bend method, shielding and site environment WTDL load-bearing shielded stage lighting cable Confirm load-bearing and dynamic bending; high-speed reeling, continuous torsion and special outdoor use require review.
Custom Engineering

What can be customized

Construction options vary by product family. The ranges below describe what can be reviewed or configured; exact minimums, maximums, tolerances and availability must be confirmed against the current specification sheet or technical evaluation.

Drag Chain CableTRVV / TRVVP / TRVVPS / TRVVPPS
Product use
Power, control, signal, twisted-pair and shielded cable selection for flexible drag-chain applications.
Conductor
High-flex fine-stranded copper; stranding can be adjusted for conductor size and dynamic bending requirements. Special conductor structures can be reviewed against the technical conditions.
Insulation & jacket
PVC or PUR options may be selected according to the product series and environment. Oil, abrasion and cold resistance require confirmation by model.
Cores / pairs
Multi-core, multi-pair and combined structures; limits depend on model, conductor size, shielding and finished diameter.
Conductor size
Multiple mm² options; signal and control products may be reviewed in AWG. Final range follows the existing specification or technical evaluation.
Dimensions
Finished diameter depends on cores, conductor size, insulation, shielding and jacket. Final dimensions and tolerances follow the confirmed specification and production inspection standard.
Length
Single coil or drum lengths can follow order requirements. Maximum production length depends on diameter, weight, reel and production conditions; any mid-joint must be confirmed before order.
Shielding
Unshielded, foil, tinned-copper braid, foil plus braid, or individual plus overall shielding may be available. Coverage follows the design and technical requirement.
Important note
Dynamic applications require additional review of travel, speed, acceleration, bend radius, operating frequency and environment. Cycle count is a test-condition result, not a direct prediction of equipment service life.
Servo CableTSFDJ / TSFDJ-P / BMQ
Product use
TSFDJ unshielded servo power drag-chain cable, TSFDJ-P shielded servo power drag-chain cable, and BMQ servo encoder/feedback cable.
Conductor
High-flex fine-stranded copper. Power conductors and signal/feedback conductors can use different structures according to current, signal transmission and dynamic movement requirements.
Insulation & jacket
Selected for power, control or encoder-feedback use, considering voltage, temperature, oil, abrasion and drag-chain movement conditions.
Cores / pairs
Power cable cores can be configured for motor supply, PE grounding and auxiliary control. Encoder and feedback cable can use multi-core, twisted-pair or composite structures based on the equipment interface.
Conductor size
Power conductor size is based on servo motor rated current; signal and feedback circuits can use smaller sizes or AWG specifications. Final ranges follow the product model.
Dimensions
Finished diameter depends on power cores, signal core quantity, shielding and jacket thickness. The confirmed specification controls final dimensions.
Length & assembly
Lengths can be customized. For connectors, terminals or finished harnesses, confirm the interface brand, model, wiring definition and both-end treatment.
Shielding
TSFDJ is unshielded. TSFDJ-P is a shielded servo power cable. BMQ uses the applicable dual-shield construction for feedback signals. Method and coverage follow the product specification.
Important note
Servo power cable and encoder/feedback cable cannot be substituted for one another and must be selected separately.
Flat Traveling CableYFFB / YFFB+2G
Product use
Flat moving and traveling cable for equipment with lifting, suspension or movement requirements.
Conductor
Flexible copper conductors arranged in parallel to create a flat construction. YFFB+2G can include a dual steel-wire structure to share mechanical tensile load during suspension and movement.
Insulation & jacket
Selected according to the equipment environment and movement requirement. Oil, cold and abrasion resistance must be confirmed separately when required.
Cores / pairs
Multi-core and combined structures are supported. Core quantity depends on cable width, conductor size, control circuits and available installation space.
Conductor size
Different mm² sizes may be selected for power, control and signal use. The final range follows the existing specification and technical evaluation.
Dimensions
Flat cable dimensions are expressed as width × thickness and change with core quantity, conductor size, support wires and jacket construction. Final dimensions and tolerances follow the confirmed specification.
Length
Length is customized to suspension height, equipment travel and installation allowance. Long suspension applications require review of cable weight, steel-wire capacity and fixation method.
Shielding
Unshielded or shielded construction can be designed for control and signal requirements. Method and coverage follow the actual model.
Important note
Dual steel wires share mechanical load; do not treat the traveling cable as the equipment’s only load-bearing member.
Energy Storage CableES-RYJ-125 and related models
Product use
High-voltage DC cable for internal power connections in energy storage equipment.
Conductor
Flexible copper or oxygen-free copper conductor; conductor size is selected according to system current, temperature rise and installation method.
Insulation & jacket
ES-RYJ-125 uses high-temperature insulation according to its product specification. Special flame-retardant, temperature or environmental requirements are confirmed against project technical conditions.
Cores / pairs
Primarily single-core power connections. Auxiliary control or combined structures require separate technical review.
Conductor size
Selected according to energy storage operating current and equipment connection requirements. Minimum and maximum ranges follow the current specification table.
Dimensions
Finished diameter changes with conductor size and insulation thickness. Final dimensions and tolerances follow the product specification and inspection standard.
Length / terminals
Lengths can be customized for battery cabinets, battery clusters, PCS units and combiner boxes. Pre-terminated options require confirmation of terminal model, hole size, crimping and heat-shrink requirements.
Shielding
Shielding is determined by the specific product design and is not reported as one universal coverage value. EMC requirements require separate evaluation.
Important note
Primarily for internal high-voltage DC power connections. It should not be assumed suitable for high-frequency drag-chain service without separate review.
EV High-Voltage CableEV / EVP / EVR / EVRP
Product use
High-voltage cable for electric vehicles and new-energy equipment, with the model selected according to the application.
Conductor
Multi-stranded flexible oxygen-free copper; conductor size and stranding are selected according to system operating current.
Insulation & jacket
Depending on model, silicone, cross-linked materials or another suitable EV high-voltage insulation and jacket construction may be used. Materials are confirmed separately by product model.
Cores / pairs
Primarily single-core high-voltage power cable. Special multi-core or composite structures require technical review.
Conductor size
Multiple high-voltage power sizes are available. The final range depends on vehicle or equipment current, temperature rise, connector and the existing specification table.
Dimensions
Finished diameter depends on conductor size, insulation, shielding and jacket. Final dimensions and tolerances follow the confirmed specification.
Length / terminals
Lengths can be customized for vehicles, battery packs, motors, controllers, high-voltage distribution and new-energy equipment. Terminals or connectors require model, drawing or physical sample confirmation.
Shielding
Unshielded models such as EV have no shield layer. Shielded models such as EVP and EVRP use foil, tinned-copper braid or a relevant composite shielding method according to construction. Coverage follows the product specification.
Important note
Selection must confirm system voltage, current, ambient temperature, installation position, shielding/grounding and terminal or connector requirements.
From Requirement to Delivery

Eight-step customization process

Standard products can be confirmed against the existing specification table. Non-standard or dynamic products first require technical evaluation of material, construction, diameter, motion and operating environment.

01

Requirement discussion

Share the equipment, installation, electrical conditions, environment and project quantity.

02

Technical review

Review the motion profile, materials, construction, diameter and applicable specification.

03

Structure & specification confirmation

Confirm the cable construction, dimensions, materials, shielding and other key parameters.

04

Quotation confirmation

Confirm pricing against the reviewed specification and commercial requirements.

05

Sample confirmation when required

Where applicable, produce or provide the sample and confirm it before volume production.

06

Volume production

Produce against the confirmed specification and order requirements.

07

In-process & final inspection

Carry out the applicable in-process and factory inspection steps.

08

Packaging & delivery

Complete packaging and delivery according to the confirmed order details.

Important: after a specification is confirmed, any major change to the parameters requires a new technical review.

RFQ Checklist

Prepare a complete cable inquiry

A complete RFQ reduces back-and-forth and gives the technical team enough context to evaluate the correct construction instead of selecting by model name alone.

Basic project information

Start with the application and commercial context.

  • Application equipment and installation method
  • Rated voltage and current
  • Number of cores or pairs
  • Conductor cross-sectional area
  • Operating temperature and environmental medium
  • Purchase quantity and single length or reel length
  • Destination and delivery requirements

If you already have a drawing, sample, connector list or target specification, include it with the inquiry.

Technical details for review

These details are required when the technical team evaluates custom or dynamic cable.

Category Information to provide
Motion Static or dynamic use; fixed, drag chain, reciprocating flexing, torsion or suspension method; minimum bend radius; travel; speed; acceleration; torsion angle and frequency
Construction Conductor, insulation and jacket materials; shielding method; finished outer-diameter limit
Environment Oil, cold, high-temperature or flame-retardant requirements
Interface Connector, terminal or harness details; required interface brand, model, wiring definition and end treatment
Project requirements Any specified standard, certification, color, printing or packaging requirement
Quality documentation Required specification, inspection or test documentation, subject to confirmation of what is available for the selected product
Application Q&A

Questions that shape the right cable

The answer depends on equipment motion, electrical conditions and installation limits. These quick answers cover the most common starting points.

What is the best cable for a drag chain application?

Start with TRVV, TRVVP, TRVVPS, TRVVPPS, TRV or an industrial drag chain Ethernet cable, then confirm travel, speed, acceleration, minimum bend radius, temperature and oil exposure. Cycle data is valid only with its test conditions and cannot be equated directly to equipment service life.

Can a servo power cable replace an encoder or feedback cable?

No. Servo power cables and encoder or feedback cables must be selected separately. Confirm motor voltage and current, cores, conductor size, PE grounding, drive interface, travel and bend radius before selection.

What do the steel wires do in a YFFB+2G flat traveling cable?

The dual steel wires provide mechanical load-sharing and tensile support. They are not conductors or shielding. Confirm suspension length, travel, speed, bend direction, minimum bend radius, support method and pulling force; the cable body should not be the equipment's sole load-bearing member.

Can energy storage cable be used in a drag chain?

ES-RYJ-125 and related energy storage cables are primarily for internal high-voltage DC power connections. High-frequency movement or drag-chain use requires separate technical confirmation and should not be assumed from fixed-installation conditions.

What should I provide for an EV high-voltage cable quote?

Provide system voltage and current, conductor size, installation position, operating temperature, minimum bend radius, shielding and grounding requirements, terminal or connector specifications, quantity, length and destination.

What information is required for a custom or stage lighting cable inquiry?

Provide the equipment, installation method, static or dynamic use, motion type, minimum bend radius, travel, speed, acceleration, torsion details, environment, voltage and current, cores or pairs, conductor size, shielding, diameter limit, quantity and length. If specified, include standard, certification, color, printing and packaging requirements.

Application Review

Have an application that does not fit a standard cable?

Share the equipment, motion profile, electrical conditions and installation environment. The technical team can review the construction and confirm what information is needed for a quotation.

Drawings, connector details, samples and target specifications are useful for technical review.

SEND YOUR RFQ→
↑
Leave a message
Email*
Phone/Whatsapp*
Company Name
Image Upload
File Upload
Message*
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.